Greener labs: energy and consumables savings that do not put samples at risk
The safest lab savings come from switching off what is idle, maintaining cooling equipment and buying only what you use. Never change a storage setting that protects samples without agreeing it with the sample owners.
Where do labs use the most energy?
Labs use most energy in ventilation, cooling and heating equipment that runs continuously. Fume hoods, ultra-low temperature freezers, incubators, ovens and chillers are the usual large items.
Start by listing what runs 24 hours a day and who owns it. You cannot save what you have not found.
What can you switch off or turn down?
- Close the fume hood sash when nobody is working at it, and turn off hoods that are not needed, where your safety officer allows it.
- Switch off instruments that you do not need overnight, but only those that do not need a warm-up or stable temperature for measurements.
- Consider running an ultra-low freezer at -70 °C if your samples tolerate it. Check with the sample owners first.
- Use water-saving or recirculating options for cooling, as your equipment allows.
How does maintenance help with energy?
A well-maintained unit uses less energy. Dusty condenser coils, worn door seals and frost build-up force a freezer to work harder and raise the risk of failure.
Put coil cleaning, defrosting and seal checks on a recurring plan. Consolidate half-empty freezers and clear out samples that no one owns, after you confirm with the owners and apply your retention rules.
How do you reduce consumables and chemical waste?
You reduce it by knowing what you already have. Duplicate orders and expired chemicals are common in labs where each group keeps its own list.
- Keep one shared stock list with expiry dates, and use the oldest lot first.
- Share rarely used items between groups instead of each group buying a pack.
- Order in sizes that match actual use, not the largest discount.
- Reuse or recycle packaging and glassware where cleanliness and safety rules allow it.
What should you never trade away?
Do not compromise safety, sample integrity or the validity of a method for a saving. Keep ventilation required by your safety rules, and do not reuse single-use items where contamination matters.
When in doubt, ask your safety officer or quality manager, and write down what you changed and why.
Where Nofira fits
Nofira keeps stock for all labs in one list with minimum levels and expiry warnings, which helps against duplicate orders, and it plans recurring maintenance such as defrosting. See inventory and maintenance.
Frequently asked questions
Is it safe to set an ultra-low freezer to -70 °C instead of -80 °C?
Many institutions run ULT freezers at -70 °C to save energy, and it is widely accepted practice. Whether it suits your samples depends on their stability requirements, so confirm with the sample owners and your quality rules first.
Where do labs usually waste the most energy?
Typically in equipment that runs around the clock or stays on while idle, such as freezers, fume hoods and ovens. Measure before you act, and begin with the largest consumers.