Using an autoclave: loading, cycles and the records to keep

Nofira editorial team 4 min read

  • autoclave
  • sterilisation
  • records

Load an autoclave loosely, with caps open and containers that tolerate steam, choose the cycle your validated method requires and record every run. Cycle settings depend on the load and the manufacturer, so never copy them from another lab.

How do you load an autoclave correctly?

Load it so that steam can reach every surface. Overpacking and tight lids are the most common reasons for a failed run.

  • Use containers that tolerate steam and pressure, such as autoclavable plastic or borosilicate glass.
  • Loosen caps and lids so that pressure can equalise. Never autoclave a sealed bottle.
  • Fill liquid containers only part way to leave room for boiling.
  • Stand bags upright in a tray and leave the neck open. Do not stack them tightly.
  • Keep waste and clean items apart, and do not put solvents, bleach or radioactive material in.

Which cycle should you choose?

Use the cycle your SOP names for that type of load. Liquids, solid waste and wrapped instruments need different programmes, and the correct hold time depends on load size and density.

If a load is new, ask your safety officer or the person responsible for the autoclave, and check the manufacturer's manual. Do not shorten a cycle to save time.

What do you do when the cycle ends?

Wait until the display shows that pressure and temperature are safe, then open the door slowly and stand clear of the steam. Hot liquids can boil over when moved, so let them cool first.

Check the indicator, the printout and the load. If the cycle faulted, do not use the load. Label it and report it.

Which records should you keep?

Keep a log entry for each run. It should be short enough that people actually fill it in.

  1. Date, time and the person who ran the cycle.
  2. Load type and the programme used.
  3. The printout or the recorded temperature, time and pressure, if your unit provides it.
  4. The indicator result and any fault or unusual observation.

Validation with biological indicators, and the interval for it, follows your institution's rules and national regulations. Pressure equipment is also inspected periodically in many countries, so record those inspections too.

How do you keep the autoclave itself in shape?

Treat it like any other instrument. Plan regular checks of the door seal, drain and water supply, and log service visits and repairs. A unit that is down on a busy day affects the whole lab.

Nofira keeps recurring maintenance plans and the full history per instrument, and a maintenance window blocks the calendar while service is under way.

Frequently asked questions

What temperature and time does an autoclave need?

It depends on the load, the container and your validated method. Many labs use cycles around 121 °C or 134 °C, but the hold time varies. Use the cycle in your SOP and the manufacturer's manual.

Does autoclave tape prove sterility?

No. Indicator tape changes colour when it has been exposed to heat or steam. It shows that the load went through a cycle, not that every part reached sterilising conditions. Biological indicators test that.